Can anyone recommend a good repairer in Adelaide that would probably come out on site? I suspect that a bridge rectifier has gone bad but don't feel confident enough to do it myself. Fuse F111 keeps blowing (flasher matrix) and everything points to BR4. I disconnected the flasher socket from the board but it still blows the fuse immediately on startup.

Also, does anyone know of a good supplier of fuses in Adelaide?

Cheers.

gamesrus
11th July 2006, 09:55 AM
Hi Mate
I can assist with the fuses
your right in thinking that if a fuse is blowing there must be a reason not being a tech myself you could try Mark southern star electronics out in pooraka
I run Amusement Worx but unfortunately a time delay is happening on work at present we are assisting the new Beach house with there machines at present and allot of operators
but give us a call can assist with the fuse
wizz:unsure

terry007
11th July 2006, 11:32 AM
Go down to your nearest Dick Smith for the fuses. They have most of what you will need.

gunigoogoo
11th July 2006, 12:22 PM
Go down to your nearest Dick Smith for the fuses. They have most of what you will need.
Cheers

Savage
11th July 2006, 12:40 PM
Can anyone recommend a good repairer in Adelaide that would probably come out on site? I suspect that a bridge rectifier has gone bad but don't feel confident enough to do it myself. Fuse F111 keeps blowing (flasher matrix) and everything points to BR4. I disconnected the flasher socket from the board but it still blows the fuse immediately on startup.

Also, does anyone know of a good supplier of fuses in Adelaide?

Cheers.

Thats, exactly what my Indi pinball was doing. Not knowing what the rectifier was (I thinks there's 3 on mine) a got 2 contacts of some techies and one come out (works for 10 pin bowling as a tech) and did the job, gave me heaps of spare bulbs and showed me.. I think all up he charged me $60.... That was to come out, supply the part and do the work!

Mickey Juice
11th July 2006, 12:56 PM
Check out http://www.marvin3m.com/fix.htm

Heaps of info eg:

A Particular Fuse Keeps Blowing in my Game when I Power-on.
First determine if a failing fuse is caused by a circuit board. The easiest way to do this is to disconnect the playfield from the board(s). This can be done by unplugging the appropriate circuit board connectors, and see if the fuse still blows.

For example, say fuse F105 keeps blowing on a WPC game. Looking at the schematics shows this is the high power solenoid fuse, and provides power to connectors J105 (cabinet), J106 (backbox), and J107 (playfield). Remove these connectors, replace fuse 105, and turn the game on. If the fuse does not blow, the problem is not on the circuit boards. If the fuse still blows, the problem is on the driver board.

If the fuse does not blow with the connectors removed, this procedure can be taken a step further. Replace connectors J105,J106,J107 one at a time, and turn the game on. Notice which connector causes the fuse to blow, and trace this connector to the device(s) in question.

If the circuit board(s) are causing a failed fuse, often a shorted bridge rectifier will cause a fuse to instantly fail when the game is turned on. See below for which fuse connects to which bridge. See the Game Resets (Bridge Rectifiers and Diodes) section for help with testing bridges. If a solenoid fuse keeps blowing after a game is started, usually that means a related driver transistor had shorted. See the Checking Transistors and Coils section for help with that.

gunigoogoo
11th July 2006, 02:02 PM
Check out http://www.marvin3m.com/fix.htm

Heaps of info eg:

A Particular Fuse Keeps Blowing in my Game when I Power-on.
First determine if a failing fuse is caused by a circuit board. The easiest way to do this is to disconnect the playfield from the board(s). This can be done by unplugging the appropriate circuit board connectors, and see if the fuse still blows.

For example, say fuse F105 keeps blowing on a WPC game. Looking at the schematics shows this is the high power solenoid fuse, and provides power to connectors J105 (cabinet), J106 (backbox), and J107 (playfield). Remove these connectors, replace fuse 105, and turn the game on. If the fuse does not blow, the problem is not on the circuit boards. If the fuse still blows, the problem is on the driver board.

If the fuse does not blow with the connectors removed, this procedure can be taken a step further. Replace connectors J105,J106,J107 one at a time, and turn the game on. Notice which connector causes the fuse to blow, and trace this connector to the device(s) in question.

If the circuit board(s) are causing a failed fuse, often a shorted bridge rectifier will cause a fuse to instantly fail when the game is turned on. See below for which fuse connects to which bridge. See the Game Resets (Bridge Rectifiers and Diodes) section for help with testing bridges. If a solenoid fuse keeps blowing after a game is started, usually that means a related driver transistor had shorted. See the Checking Transistors and Coils section for help with that.
Thanks for the great info. That's what I tried and I'm pretty sure it's the bridge rectifier as it still blows the fuse with the connectors removed.

So does anyone know a tech in Adelaide who will do callouts?

Ric
11th July 2006, 03:11 PM
if you have a DMM you can test the rectifier to see if it is blown?

otherwise, just remove the board and drop it to tech place (pinball or otherwsie) and they should be able to change the rectifier (about a $4 part)

or you can try it yourself - i take no responsiblity for any fried boards, smoke or other electrically related mishap

terry007
11th July 2006, 03:32 PM
So does anyone know a tech in Adelaide who will do callouts?

Did you try Southern Star at Pooraka?

Or "quote" from Dickesons on South Rd


Service
We can boast the largest service department in South Australia. We have 7 full time servicemen that work from our premises at Edwardstown. We have specialists in CD jukeboxes & pinball machines (dot matrix displays only), video games etc.

We can service your equipment at our workshop. We will not do call outs, however, if you require your equipment picked up and delivered back we can do this for $50 in metro area (no upstairs or downstairs pickups). We do not give service advice over the phone. Our service section is open from Monday - Friday 9am to 5pm. Our standard labour rate is $55 per hour (incl GST) plus parts.

gunigoogoo
11th July 2006, 03:36 PM
if you have a DMM you can test the rectifier to see if it is blown?

otherwise, just remove the board and drop it to tech place (pinball or otherwsie) and they should be able to change the rectifier (about a $4 part)

or you can try it yourself - i take no responsiblity for any fried boards, smoke or other electrically related mishap
How do you do that? Is it on the TESTS menu?

Ric
11th July 2006, 04:43 PM
sorry

DMM = digital multi meter

DMD = dot matrix display

if you have a multi meter you can probe the bridge to see if has shorted

no test in the setup for the power boards only software/audits/switches

Ric